| home / news | products | downloads | special offers | contact us | links | search the site

MACNAUGHT M Series FLOW METERS

 

download flowmeter selection form

download flowmeter selection programme

A comprehensive range of low cost / high spec flow meters with model options suited to a varied and diverse array of fluid media applications. Installation is simple and flexible for both pump and gravity fed systems, and to make life easier M-Series meters are exceptionally durable and simple to service in the field.

Contact Hydrotechnik for a Macnaught Flow Meter Selection CD

Download the Macnaught Flow meter selection programme

Meter / accessory options

> M1 0.03 to 1.6 Litres/min

> M2 0.25to 8.33Litres/min

> M41 to 30Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

> M50 15 to 350 Litres/min

> Accessories

> Displays

> Top of page

Operating Principle

M-Series flow meters are based on the proven oval rotor principle, ensuring high accuracy and repeatability. Precision engineering eliminates pockets in which liquid can stagnate within the measuring chamber of the flow meter.
A pair of intermeshing ellipsoidal gears rotate on shafts and sweep the chamber. Each rotation measures a small volume of trapped liquid, independent of viscosity or density. Magnets located in the gears enable each rotation to be picked up by reed switches or hall sensors located in a secondary chamber within the meter body. A nominal pulses per litre value is arrived at in this way.
Each meter is individually tested to ensure that it performs within calibration parameters. The results are detailed on the NATA traceable certificate which accompanies each flow meter.

Blank


Reliability

M-Series meters are designed to contain very few wearable and replaceable parts. Meter construction enables fast and easy on-site servicing without the need to remove the body from the pipe work.

M1 & M2 low flow models

The smallest models in the M-Series range provide low cost high resolution pulse meters capable of measuring fluids with viscosity's from 1 to 1000 centipoise. Body and rotor materials are either PPS or 316 S/Steel with Hastalloy C shafts available for extremely aggressive chemicals. Pulse output is either Hall effect or reed switch.

M5 to M50 small to high flow models

Higher pressure ratings than the standard M1 & M2 as well as a variety of connection types, pulse output and display options make for a high degree of diversity among the rest of the models within the M-Series range.
Aluminium or 316 S/steel bodies and a choice of PPS or S/Steel rotors are some of the options designed to help you tailor the flow meter to your particular needs. All models feature exceptionally low pressure drops of less than 1 Bar at full flow allowing for economical pump selection or gravity fed applications.

Display Options

Head mounted and remote display options specific to M-Series meters are available, although various output options ensure M-Series meters are compatible with many types of third party instrumentation.

Applications

M-Series meters will accurately measure, mix, batch and dose an extremely wide variety of fluid mediums including aggressive and intrinsically safe applications. A choice of construction and sealing materials coupled with high viscosity and high temperature options enable the engineer to select a model which is tailored to the application at hand.


M1 Series 1/4" Flow Meters

M1 - 1/4" Pulse Meters

The M1 is the smallest capacity meter in the range. An excellent turn-down 100:1 and high resolution (1 pulse per cc) make this meter an ideal choice for accurate low flow metering.

It has the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability.

A New high pressure M1 (551 bar) has recently been introduced

> M2 0.25 to 8.33 Litres/min

> M4 1 to 30 Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

>M50 15 to 350 Litres/min

> Accessories

> Displays

>Top of page

Model

M1RSP-XY

M1SSP-XY

M1SSPH-X

Meter Type

Pulse

Pulse

Pulse

Meter Body Material

PPS

316 Stainless Steel

316 Stainless Steel

Wetted Components:

Rotor Material

316 S/St or PPS option

316 Stainless Steel

316 Stainless Steel

Shafts

316 St/Steel or Hastalloy Opt

316 Stainless Steel

316 Stainless Steel

O'ring

Viton- Standard

Viton- Standard

Viton- Standard

Flow Rate Ranges (litres per hour/US gallons per hour)

Above 5 CPS

2 to 100 / 0.53to 26.4

2 to 100 / 0.53 to 26.4

2 to 100 / 0.53to 26.4

Below 5 CPS

5 to 100 / 1.32 to 26.4

5 to 1007 / 1.32 to 26.4

5 to 100 / 1.32 to 26.4

Accuracy within (of reading)

+/- 1%

+/- 1%

+/- 1%

Repeatability

0.03%

0.03%

0.03%

Maximum Viscocity

1000 Centipoise

1000 Centipoise

1000 Centipoise

Maximum Operating Pressure

500kPa/ 75 PSI/ 5 BAR

1000kPa/ 150PSI/ 10BAR

55160kPa/ 8000PSI/ 551BAR

Pulser Type

Hall Effect Sensor or Reed Switch

Hall Effect Sensor or Reed Switch

Hall Effect Sensor

Pulses per litre/US Gallon

1000 / 3785.4

1000 / 3785.4

1000 / 3785.4

Model Dimensions

Meter Body

50x50mm / 1.97"x1.97"

50x50mm / 1.97"x1.97"

86mm dia x 110mm h / 3.4" dia x 4.33" h

Port face to face

65mm / 2.58"

65mm / 2.58"

83mm / 3.26"

Weight

240g / 8.5oz

600g / 21.2oz

3.3kg / 116.5oz

Max. Operating Temperature

80°C / 176°F

120°C / 248°F

120°C / 248°F

Recommended Mesh
strainer size

200 Mesh

200 Mesh

200 Mesh

 


M2 Series 1/4" Flow Meters

M2 - 1/4" Pulse Meters

The M2 is one of the small capacity meters in the range . It has a low to medium flow range which has made it a very popular model.

It has the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability

A New high pressure M2 (551 bar) has recently been introduced

> M1 0.03 to 1.6 Litres/min

> M4 1 to 30 Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

> M50 15 to 350 Litres/min

> Accessories

> Displays

> Top of page

Model

M2RSP-XY

M2SSP-XY

M2SSPH-XY

Meter Type

Pulse

Pulse

Pulse

Meter Body Material

PPS

316 Stainless Steel

316 Stainless Steel

Wetted Components

Rotor Materials

316 St/Steel or PPS Option

316 Stainless Steel

316 Stainless Steel

Shafts

316 St/Steel or Hastalloy Opt

316 Stainless Steel

316 Stainless Steel

O'ring

VITON- Standard

VITON- Standard

VITON- Standard

Flow Rate Ranges (litres per hour/US gallons per hour)

Above 5 CPS

15 to 500 / 4 to 132

15 to 500 / 4 to 132

15 to 500 / 4 to 132

Below 5 CPS

25 to 500 / 6 to 132

25 to 500 / 6 to 132

25 to 500 / 6 to 132

Accuracy within (of reading)

+/- 1%

+/- 1%

+/- 1%

Repeatability

0.03%

0.03%

0.03%

Maximum Viscosity

1000 Centipoise

1000 Centipoise

1000 Centipoise

Max. Operating Pressure

500kPa/ 75 PSI/ 5 BAR

1000kPa/ 150PSI/ 10BAR

551600kPa/ 8000PSI/ 551BAR

Pulser type

Hall Effect Sensor or Reed Switch

Hall Effect Sensor or Reed Switch

Hall Effect Sensor

Pulses per litre/US Gallon

400 / 1514.2

400 / 1514.2

400 / 1514.2

Model Dimensions

Meter Body

50x50mm / 1.97"x1.97"

50x50mm / 1.97"x1.79"

86mm dia x 110mm h
3.4" dia x 4.33" h

Port Face to Face

65mm / 2.58"

65mm / 2.58"

83mm / 3.26"

Weight

240g / 8.5oz

600g / 21.2oz

3.3kg /116.5oz

Max. Operating Temperature

80°C / 176°F

120°C / 248°F

120°C / 248°F

Recommended Mesh Strainer Size

200 Mesh

200 Mesh

200 Mesh

 


M4 Series - 1/2" Flow Meters

The M5 series are the small to medium capacity meters in the Macnaught range. They have the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability. EEx d Certified

Optional features include:

  • Dual pulse output
  • Analogue output
  • High viscosity rotors (up to1,000,000 Centipoise)
  • Head-mounted Rate/Totaliser and Batch controller LCD Display (EEx ia 0ption)
  • Mechanical Display option

> M1 0.03 to 1.6 Litres/min

> M2 0.25 to 8.3 Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

> M50 15 to 350 Litres/min

> Accessories

> Displays

> Top of page

Model

M4ARP-X

M4ASP-X

M4SRP-X

M4SSP-X

Meter Type

Pulse

Pulse

Pulse

Pulse

Meter Body Material

AA601 Aluminium

AA601 Aluminium

316 Stainless Steel

316 Stainless Steel

Wetted Components

Rotor Material

PPS

316 Stainless Steel

PPS

316 Stainless Steel

Shafts

316 Stainless Steel

316 Stainless Steel

316 Stainless Steel

316 Stainless Steel

O'ring

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

Flow Rate Ranges (litres per minute/US gallons per minute)

Above 5 CPS

1 to 30 / 0.26 to 8

1 to 30 / 0.26 to 8

1 to 30 / 0.26 to 6.60

1 to 30/ 0.26 to 8

Below 5 CPS

3 to 25 / 0.8 to 6.60

3 to 25 / 0.8 to 6.60

3 to 25 / 0.8 to 6.60

3 to 25 / 0.8 to 6.60

Accuracy within (of reading)

+/- 0.5%

+/- 0.5%

+/- 0.5%

+/- 0.5%

Repeatability

0.03%

0.03%

0.03%

0.03%

Maximum Viscosity (of standard model)

1000 Centipoise

1000 Centipoise

1000 Centipoise

1000 Centipoise

Maximum Operating Temperature

5500kPa/ 800 PSI/ 55 BAR

5500kPa/ 800 PSI/ 55 BAR

5500kPa/ 800 PSI/ 55 BAR

5500kPa/ 800 PSI/ 55 BAR

Pulser Type

Hall Effect or Reed Switch or Combination HE / RS

Hall Effect or Reed Switch or Combination HE / RS

Hall Effect or Reed Switch or Combination HE / RS

Hall Effect or Reed Switch or Combination HE / RS

Pulses per litre/US Gallon

81 OR 162 / 306.6 0R 613.2

81 OR 162 / 306.6 0R 613.2

81 OR 162 / 306.6 0R 613.2

81 OR 162 / 306.6 0R 613.2

Model Dimensions

Meter Body

112mm dia x 125mm h
4.41" dia x 4.92" h

112mm dia x 125mm h
4.41" dia x 4.92" h

112mm dia x 125mm h
4.41" dia x 4.92" h

112mm dia x 125mm h
4.41" dia x 4.92" h

Port Face to Face

125mm / 4.92"

125mm / 4.92"

125mm / 4.92"

125mm / 4.92"

Weight

1.8kg / 3.96lbs

1.8kg / 3.96lbs

2.9kg / 6.39lbs

2.9kg / 6.39lbs

Max. Operating Temperature

80°C / 176°F

120°C / 248°F

80°C / 176°F

120°C / 248°F

Recommended Mesh
Strainer Size

60 Mesh

60 Mesh

60 Mesh

60 Mesh

 

M7 Series - 1" Flow Meter - SUPER ACID PROOF METER

The M7 series is the meter of choice for low cost metering of acids or water based liquids.

Prices from £335.00

Optional features include:

  • Dual pulse output
  • Analogue output
  • High viscosity rotors (up to1,000,000 Centipoise)
  • High temperature version available
  • Head mounted or remote LCDs
  • IS versions available
  •  

> M1 0.03to 1.6 Litres/min

> M2 0.25 to 8.3 Litres/min

> M4 1 to 30Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

> M50 15 to 350 Litres/min

> Accessories

> Displays

> Top of page

Model

M7APP-X

Meter Type

Pulse

Meter Body Material

PPS

Wetted Components

Rotor Material

PPS

Shafts

PPS

O'ring

VITON

Flow Rate Ranges litres per minute

Above 5 CPS

3 to 80 L/min

Below 5 CPS

8 to 70 L/min

Accuracy within (of reading)

+/- 0.5%

Repeatability

0.03%

Maximum Viscosity (of standard model)

1000 Centipoise

Maximum Operating Temperature

5500kPa/ 800 PSI/ 55 BAR

Pulser Type

Hall Effect or Reed Switch or Combination HE / RS

Pulses per litre

52 OR 104

Model Dimensions

Meter Body

100mm dia x 120mm h

Port Face to Face

108mm / 4.92"

Weight

0.9kg

Max. Operating Temperature

80°C

Recommended Mesh
Strainer Size

60 Mesh

M10 - 1" Flow Meters

The M10 series are the small to medium capacity meters in the Macnaught range. They have the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability. EEx d Certified

Optional features include:

  • Dual pulse output
  • Analogue output
  • High viscosity rotors (up to1,000,000 Centipoise)
  • Head-mounted Rate/Totaliser and Batch controller LCD Display (EEx ia option)
  • Mechanical register option
  •  

> M1 0.03 to 1.6 Litres/min

> M2 0.25 to 8.3 Litres/min

> M4 1 to 30 Litres/min

> M7 3 to 80 Litres/min

> M40 10 to 250 Litres/min

> M50 15 to 350 Litres/min

> Accessories

> Displays

> Top of page

Model

M10ARE-X

M10ASE-X

M10SRE-X

M10SSE-X

M10BRE-X

Meter type

Pulse with delux LC display

Pulse with delux LC display

Pulse with delux LC display

Pulse with delux LC display

Pulse with delux LC display

Meter body material

AA601 Aluminium

AA601 Aluminium

316 Stainless steel

316 316 Stainless steel

Bronze

Wetted components:

Rotor Material

PPS

316 Stainless steel

PPS

316 Stainless steel

PPS

Shafts

316 Stainless steel

316 Stainless steel

316 Stainless steel

316 Stainless steel

316 Stainless steel

O'Ring

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

Flow Rate Ranges (litres per minute/US gallons per minute)

Above 5 CPS

6 to 120 / 1.6 to 32

6 to 120 / 1.6 to 32

6 to 120 / 1.6 to 32

6 to 120 / 1.6 to 32

6 to 120 / 1.6 to 32

Below 5 CPS

10 to 100 / 2.6 to 26

10 to 100 / 2.6 to 26

10 to 100 / 2.6 to 26

10 to 100 / 2.6 to 26

10 to 100 / 2.6 to 26

Accuracy within (of reading)

+/- 0.5%

+/- 0.5%

+/- 0.5%

+/- 0.5%

+/- 0.5%

Repeatability

0.03%

0.03%

0.03%

0.03%

0.03%

Maximum viscocity of standard model

1000 Centipoise

1000 Centipoise

1000 Centipoise

1000 Centipoise

1000 Centipoise

Maximum operating pressure

5500kPa/ 800 PSI/ 55 BAR or flange rule where fitted

Pulser type

Reed switch or combination HE / RS

Reed switch or combination HE / RS

Reed switch or combination HE / RS

Reed switch or combination HE / RS

Reed switch or combination HE / RS

Pulses per litre/
US gallon

36 /136.3

36 /136.3

36 /136.3

36 /136.3

36 /136.3

Max. operating temperature

80°C / 176°F

120°C / 248°F

80°C / 176°F

120°C / 248°F

80°C / 176°F

Recommended mesh strainer size

60 Mesh

60 Mesh

60 Mesh

60 Mesh

60 Mesh

 


M40 - 1.5" Flow Meters

The M40 series are medium capacity meters in the Macnaught range. They have the ability to handle a wide range of fluid viscosities with exceptional levels of repeatability and durability. EEx d Certified

Optional features include:

  • Dual pulse output
  • Analogue output
  • High viscosity rotors (up to1,000,000 Centipoise)
  • Head-mounted Rate/Totaliser and Batch controller LCD Display (EEx ia option)
  • Mechanical register option
  •  

> M1 0.03 to 1.6 Litres/min

> M2 0.25 to 8.3 Litres/min

> M4 1 to 30 Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M50 15 to 350 Litres/min

> Accessories

> Displays

> Top of page

Model

M40ARP-X

M40ASP-X

M40SRP-X

M40SSP-X

Meter type

PULSE

PULSE

PULSE

PULSE

Meter body material

AA601 Aluminium

AA601 Aluminium

316 Stainless steel

316 Stainless steel

Wetted components

Rotor material

PPS

316 Stainless steel

PPS

316 Stainless steel

Shafts

316 Stainless steel

316 Stainless steel

316 Stainless steel

316 Stainless steel

'O'Ring

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

NBR (Nitrile)

Flow rate ranges (litres per minute/US gallons per minute)

Above 5 CPS

10 to 250 / 2.6 to 66

10 to 250 / 2.6 to 66

10 to 250 / 2.6 to 66

10 to 250 / 2.6 to 66

Below 5 CPS

15 to 235 / 4 to 62

15 to 235 / 4 to 62

15 to 235 / 4 to 62

15 to 235 / 4 to 62

Accuracy within (of reading)

+/- 0.5%

+/- 0.5%

+/- 0.5%

+/- 0.5%

Repeatability

0.03%

0.03%

0.03%

0.03%

Maximum viscosity of standard model

1000 Centipoise

1000 Centipoise

1000 Centipoise

1000 Centipoise

Maximum operating pressure

5500kPa/ 800 PSI/ 55 BAR or flange rule where fitted

Pulser type

Hall effect or Reed switch or combination HE / RS

Hall effect or Reed switch or combination HE / RS

Hall effect or Reed switch or combination HE / RS

Hall effect or Reed switch or combination HE / RS

Pulses per litre/US gallon

14.5 OR 29 / 54.9 0R 109.8

14.5 OR 29 / 54.9 0R 109.8

14.5 OR 29 / 54.9 0R 109.8

14.5 OR 29 / 54.9 0R 109.8

Maximum operating temperature

80°C / 176°F

120°C / 248°F

80°C / 176°F

120°C / 248°F

Recommended mesh strainer size

60 Mesh

60 Mesh

60 Mesh

60 Mesh

 


M50 - 2" Pulse Meters

> M1 0.03 to 1.6 Litres/min

> M2 0.25 to 8.3 Litres/min

> M4 1 to 30 Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

> Accessories

> Displays

> Top of page

The M50 series are the high capacity meters in the Macnaught range. They have all the benefits of the smaller models with extra mechanical options.

Model

M50ARP-X

M50SRP-X

Meter Type

Pulse

Pulse

Meter Body Material

AA601 Aluminium

316 Stainless Steel

Wetted Components

Rotor Material

PPS

PPS

Shafts

316 Stainless Steel

316 Stainless Steel

O'ring

NBR (Nitrile)

NBR (Nitrile)

FlowRate Ranges (litres per minute/US gallons per minute)

Above 5 CPS

15 to 350 / 3.96 to 92.46

15 to 350 / 3.96 to 92.46

Below 5 CPS

30 to 300 / 7.93 to 79.25

30 to 300 / 7.93 to 79.25

Accuract within (of reading)

+/- 0.5%

+/- 0.5%

Repeatability

0.03%

0.03%

Maximum Viscosity (of Standard Model)

1000 Centipoise

1000 Centipoise

Maximum Operating Pressure

As per flange rule

As per flange rule

Pulser Type

Hall Effect or Reed Switch
or combination HE / RS

Hall Effect or Reed Switch
or combination HE / RS

Pulses per litre/US Gallons

6.68 / 25.29

6.68 / 25.29

Max. Operating Temperature

80°C / 176°F

80°C / 176°F

Recommended Mesh Strainer Size

60 Mesh

60 Mesh

 


Accessories

> M1 0.03 to 1.6 Litres/min

> M2 0.25 to 8.3 Litres/min

> M4 1 to 30 Litres/min

> M7 3 to 80 Litres/min

> M10 6 to 120 Litres/min

> M40 10 to 250 Litres/min

> M50 15 to 350 Litres/min

>Displays

> Top of page

Optional O'rings

Various optional O'Rings are available for the M Series range to allow the flowmeters to have maximum flexibility in most applications.
For the
M1 and M2, both EPDM and Teflon encapsulated O'Rings are available. The M4, M10, M40 and M50 are available with Viton, EPDM and Teflon encapsulated O'Rings.

Optional - High Temperature Rotors

For fluid temperatures above 80°C/176°F and up to 120°C/248°F, operators may select 'high temperature' rotors. This option only applies for the PPS rotor models of the M4, M10, M40 and M50 as meters fitted with stainless steel rotors are capable of handling temperatures up to 120°C/248°F. (Except mechanical version which are limited to 80°C/176°F).

Optional - High Viscosity Rotors

For fluids above 1000cps, viscosity, optional high viscosity PPS or stainless steel rotors can be specified for M4, M10, M40 and M50 (PPS only) models. If necessary consult your local distributor for additional technical assistance as the flow rate will vary in accordance with fluid viscosity (See page 26).

Optional - Hall Effect Sensor

The M4, M10, M40 and M50 pulse models can be optionally fitted with two digital output Hall Effect Switches to eliminate oscillation (pulse bounce) experienced with standard reed switches.
The HE Switches are 3-wire solid state NPN output devices with 4.5 - 24-volt DC supply voltage ratings. A common power supply must be used.
Note: When Hall Effect Sensors are fitted, only the lesser pulse output is available although the two sensors can be used for dual outputs. A single Hall Effect Sensor is standard on
M1 and M2 models.

Optional - Solvent Kit (Mechanical display meters only)

Mechanical versions of the M10, M40 and M50 aluminium models can be fitted with a special seal kit for use with most common solvents. This kit is standard on all stainless steel mechanical models.

Optional - Hastalloy C Shafts

Special Hastalloy C Shafts are available for the M1 and M2 PPS body meters for use with extremely aggressive chemicals.

Accessory - Extended Life Battery

DELUXE LC DISPLAY ONLY
A silicon protection boot is available when the meter is used in an aggressive atmosphere. Accessory part number is B500.

Accessory - Head Mounted or Remote Mounted LC Displays

These displays can be head mounted on to M-Series pulse meters originally supplied without a display, or supplied with mounting brackets and mounted remotely. They can be connected also to the auxiliary pulse output of a local display meter for use as a second remote display. Accessory part numbers are F500 (deluxe version EEx ia Rate/Total + batching facilities) and G500 (standard version Rate/Total + Re-set)

DELUXE LC DISPLAY ONLY
The service life of the battery supplied in the deluxe display is approximately one year.

This replacement Lithium 3-volt (CR123A) extended life battery will approximately double the service period but the "intrinsically safe" feature will be lost. Accessory part number is L500.


Displays

> Standard LC Display

> Deluxe LC Display

> Mechanical Display

> Meters

> Accessories

> Top of page

 

Standard LC Display

> Deluxe LC Display

> Mechanical Display

> Meters

> Accessories

> Top of page

The standard LC Display is available on specific M4, M10, M40 and M50 series models. It is also available as an accessory so it can be used as a remote mounted display for any M Series meter model supplied without a display e.g. M1, M2, M10 etc.

Features
  • 8 Digit x10mm/ 3/8" Liquid Crystal Display.
  • Display can be rotated in 90° steps.
  • Flow rate display in litres or US gallons (according to model selected).
  • 2 total displays - resettable and non-resettable, up to 999,999.99 litres or US gallons (according to model selected).
  • Factory set calibration constant (K factor).
  • Long life 9-volt Lithium battery.
  • Pulse output for ancillary equipment.

Deluxe LC Display

> Standard LC Display

> Mechanical Display

> Meters

> Accessories

> Top of page

The deluxe LC Display is available on specific M4, M10, M40 and M50 series models. It is also available as an accessory so it can be used as a remote mounted display for any M Series meter model supplied without a display e.g. M1, M2, M10 etc.

Features
  • 7 Digit x 12.7mm (1/2") Liquid Crystal Display.
  • Display can be rotated in 90° steps.
  • Selectable flow rate display in litres or US gallons.
  • 2 total displays.
  • Up to 999,999.9 litres or US gallons (resettable).
  • Pre-settable batch control function up to 9,999 units (99.99, 999.9 or 9,999 optional settings).
  • 10 preset batch quantity storage capacity.
  • 3 digit cycle counter for batch dispensed.
  • Single or two stage valve actuation output to be used with appropriate trip amplifier.
  • Factory set calibration constant (K Factor).
  • Additional 9 calibration constants (K Factors) available for "in-the-field" settings.
  • Up to 9,999,999 litres or US gallons (non-resettable).
  • Pulse output for ancillary equipment.
  • Long Life 3-volt Lithium / CR2040 battery. (Extended life battery available as an option - see page 22).
  • Approved for hazardous locations (standard battery only) EEx ia IIC T6 (PTB nr. Ex-93.C 4033X).

Mechanical Display

> Standard LC Display

> Deluxe LC Display

> Meters

> Accessories

> Top of page

The Mechanical Display is available on specific M4 M10 M40and M50 Series meter models.

Features
  • Litre or US gallon display (according to model selected).
  • Two Total displays; - 1 to 9,999 litres or 1/10 to 999.9 US gallons (Resettable) - 1 to 999,999 litres (X10) or 1 to 999,999 US gallons (Non-Resettable).
  • Push button reset.
  • Display can be rotated in 90° steps.

 

Back to the top of the page
Minimess Pressure test points | Hand held Test & Data logging | Flow Meters | Macnaught | Schroeder Filtration | Flow Displays | Site Navigation | Contact us | Special Offers | Company results | HydroWin | Downloads |
All New Catalogue | Links